{"id":1368,"date":"2024-06-08T09:17:04","date_gmt":"2024-06-08T00:17:04","guid":{"rendered":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/?p=1368"},"modified":"2024-06-08T09:24:10","modified_gmt":"2024-06-08T00:24:10","slug":"perfusion-ct%e3%81%ae%e8%99%9a%e8%a1%80%e8%a8%ba%e6%96%ad%e8%83%bd%e3%81%a8%e4%ba%88%e5%be%8c%e4%ba%88%e6%b8%ac%e8%83%bd%e3%81%ab%e9%96%a2%e3%81%99%e3%82%8b%e8%ab%96%e6%96%87%e3%81%8cehj-cardiovascula","status":"publish","type":"post","link":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/perfusion-ct%e3%81%ae%e8%99%9a%e8%a1%80%e8%a8%ba%e6%96%ad%e8%83%bd%e3%81%a8%e4%ba%88%e5%be%8c%e4%ba%88%e6%b8%ac%e8%83%bd%e3%81%ab%e9%96%a2%e3%81%99%e3%82%8b%e8%ab%96%e6%96%87%e3%81%8cehj-cardiovascula\/","title":{"rendered":"Perfusion CT\u306e\u865a\u8840\u8a3a\u65ad\u80fd\u3068\u4e88\u5f8c\u4e88\u6e2c\u80fd\u306b\u95a2\u3059\u308b\u8ad6\u6587\u304cEHJ Cardiovascular Imaging\u306b\u63b2\u8f09\u3055\u308c\u307e\u3057\u305f\u3002"},"content":{"rendered":"\n<p><strong>\u8ad6\u6587\u60c5\u5831<\/strong><\/p>\n\n\n\n<p>\u30bf\u30a4\u30c8\u30eb\uff1aValue of Dynamic Computed Tomography Myocardial Perfusion in CAD: A Systematic Review and Meta-analysis<\/p>\n\n\n\n<div style=\"height:26px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u8457\u8005\uff1a Yuma Kawaguchi, Shingo Kato, Nobuyuki Horita, Daisuke Utsunomiya<\/p>\n\n\n\n<p>\u63b2\u8f09\u96d1\u8a8c\uff1a Eur Heart J Cardiovasc Imaging. 2024 May 2:jeae118. doi: 10.1093\/ehjci\/jeae118.<\/p>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u5fc3\u81d3CT\u306f\u51a0\u52d5\u8108\u72ed\u7a84\u306e\u8a55\u4fa1\u3060\u3051\u3067\u306a\u304f\u3001\u51a0\u52d5\u8108\u30d7\u30e9\u30fc\u30af\u3084\u5fc3\u7b4b\u306e\u6027\u72b6\u8a55\u4fa1\u306b\u3082\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u30e1\u30bf\u89e3\u6790\u3092\u884c\u3044\u3001\u5fc3\u7b4b\u865a\u8840\u306e\u8a55\u4fa1\u3092\u884c\u3046dynamic CT perfusion\u306b\u3064\u3044\u3066\u3001\u5fc3\u7b4b\u865a\u8840\u306e\u8a3a\u65ad\u80fd\u3068\u5fc3\u8840\u7ba1\u30a4\u30d9\u30f3\u30c8\u306e\u4e88\u6e2c\u80fd\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u60a3\u8005\u30d9\u30fc\u30b9\u306e\u89e3\u6790\u3067\u306f\u3001CT-MBF\u306esROC\u66f2\u7dda\u4e0b\u9762\u7a4d\u306f0.93\u3067\u3001\u611f\u5ea6\u306f0.84\u3001\u7279\u7570\u5ea6\u306f0.88\u3067\u3057\u305f\u3002CT\u306e\u7a2e\u985e\uff08\u30c7\u30e5\u30a2\u30eb\u30bd\u30fc\u30b9\u5bfe\u30b7\u30f3\u30b0\u30eb\u30bd\u30fc\u30b9\uff09\u3084\u4f53\u683c\u6307\u6570\uff08BMI\uff09\u306e\u9055\u3044\u306f\u3001\u8a3a\u65ad\u6027\u80fd\u306b\u6709\u610f\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u305b\u3093\u3067\u3057\u305f\u3002Dynamic CT perfusion\u306b\u3088\u308b\u6709\u5bb3\u4e8b\u8c61\u4e88\u6e2c\u306e\u305f\u3081\u306e\u7d71\u5408\u30cf\u30b6\u30fc\u30c9\u6bd4\u306f4.98\uff0895%CI: 2.08-11.93, p=&lt;0.001, I\u00b2=61%, \u7570\u8cea\u6027\u306ep=0.07\uff09\u3067\u3057\u305f\u3002\u3053\u306e\u3088\u3046\u306b\u826f\u597d\u306a\u7d50\u679c\u3067\u3042\u308a\u3001dynamic CT perfusion\u306b\u3088\u308b\u865a\u8840\u8a3a\u65ad\u306f\u4eca\u5f8c\u81e8\u5e8a\u306b\u5e83\u307e\u308b\u30dd\u30c6\u30f3\u30b7\u30e3\u30eb\u304c\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8ad6\u6587\u60c5\u5831 \u30bf\u30a4\u30c8\u30eb\uff1aValue of Dynamic Computed Tomography Myocardial Perfusion in CAD: A Systematic Review and Meta-analy [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13,7],"tags":[],"class_list":["post-1368","post","type-post","status-publish","format-standard","hentry","category-academic-activity","category-7"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/posts\/1368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/comments?post=1368"}],"version-history":[{"count":11,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/posts\/1368\/revisions"}],"predecessor-version":[{"id":1380,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/posts\/1368\/revisions\/1380"}],"wp:attachment":[{"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/media?parent=1368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/categories?post=1368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www-user.yokohama-cu.ac.jp\/~diagrad\/wp-json\/wp\/v2\/tags?post=1368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}